Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuroradiology ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492021

RESUMO

PURPOSE: Vessel-encoded arterial spin labeling (VE-ASL) is able to provide noninvasive information about the contribution of individual arteries to the cerebral perfusion. The aim of this study was to compare VE-ASL to the diagnostic standard digital subtraction angiography (DSA) with respect to its ability to visualize vascular territories. METHODS: In total, 20 VE-ASL and DSA data sets of 17 patients with Moyamoya angiopathy with and without revascularization surgery were retrospectively analyzed. Two neuroradiologists independently assessed the agreement between VE-ASL and DSA using a 4-point Likert scale (no- very high agreement). Additionally, grading of the vascular supply of subterritories (A1-A2, M1-M6) on the VE-ASL images and angiograms was performed. The intermodal agreement was calculated for all subterritories in total and for the subdivision into without and after revascularization (direct or indirect bypass). RESULTS: There was a very high agreement between the VE-ASL and the DSA data sets (median = 1, modus = 1) with a substantial inter-rater agreement (kw = 0.762 (95% CI 0.561-0.963)). The inter-modality agreement between VE-ASL and DSA in vascular subterritories was almost perfect for all subterritories (k = 0.899 (0.865-0.945)), in the subgroup of direct revascularized subterritories (k = 0.827 (0.738-0.915)), in the subgroup of indirect revascularized subterritories (k = 0.843 (0.683-1.003)), and in the subgroup of never revascularized subterritories (k = 0.958 (0.899-1.017)). CONCLUSION: Vessel-encoded ASL seems to be a promising non-invasive method to depict the contributions of individual arteries to the cerebral perfusion before and after revascularization surgery.

2.
Radiol Med ; 129(3): 478-487, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38349416

RESUMO

INTRODUCTION: Low back pain is a global health issue causing disability and missed work days. Commonly used MRI scans including T1-weighted and T2-weighted images provide detailed information of the spine and surrounding tissues. Artificial intelligence showed promise in improving image quality and simultaneously reducing scan time. This study evaluates the performance of deep learning (DL)-based T2 turbo spin-echo (TSE, T2DLR) and T1 TSE (T1DLR) in lumbar spine imaging regarding acquisition time, image quality, artifact resistance, and diagnostic confidence. MATERIAL AND METHODS: This retrospective monocentric study included 60 patients with lower back pain who underwent lumbar spinal MRI between February and April 2023. MRI parameters and DL reconstruction (DLR) techniques were utilized to acquire images. Two neuroradiologists independently evaluated image datasets based on various parameters using a 4-point Likert scale. RESULTS: Accelerated imaging showed significantly less image noise and artifacts, as well as better image sharpness, compared to standard imaging. Overall image quality and diagnostic confidence were higher in accelerated imaging. Relevant disk herniations and spinal fractures were detected in both DLR and conventional images. Both readers favored accelerated imaging in the majority of examinations. The lumbar spine examination time was cut by 61% in accelerated imaging compared to standard imaging. CONCLUSION: In conclusion, the utilization of deep learning-based image reconstruction techniques in lumbar spinal imaging resulted in significant time savings of up to 61% compared to standard imaging, while also improving image quality and diagnostic confidence. These findings highlight the potential of these techniques to enhance efficiency and accuracy in clinical practice for patients with lower back pain.


Assuntos
Aprendizado Profundo , Dor Lombar , Humanos , Dor Lombar/diagnóstico por imagem , Inteligência Artificial , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Vértebras Lombares/diagnóstico por imagem , Artefatos , Processamento de Imagem Assistida por Computador/métodos
3.
J Neuroimaging ; 34(2): 232-240, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38195858

RESUMO

BACKGROUND AND PURPOSE: This study explores the use of deep learning (DL) techniques in MRI of the orbit to enhance imaging. Standard protocols, although detailed, have lengthy acquisition times. We investigate DL-based methods for T2-weighted and T1-weighted, fat-saturated, contrast-enhanced turbo spin echo (TSE) sequences, aiming to improve image quality, reduce acquisition time, minimize artifacts, and enhance diagnostic confidence in orbital imaging. METHODS: In a 3-Tesla MRI study of 50 patients evaluating orbital diseases from March to July 2023, conventional (TSES ) and DL TSE sequences (TSEDL ) were used. Two neuroradiologists independently assessed the image datasets for image quality, diagnostic confidence, noise levels, artifacts, and image sharpness using a randomized and blinded 4-point Likert scale. RESULTS: TSEDL significantly reduced image noise and artifacts, enhanced image sharpness, and decreased scan time, outperforming TSES (p < .05). TSEDL showed superior overall image quality and diagnostic confidence, with relevant findings effectively detected in both DL-based and conventional images. In 94% of cases, readers preferred accelerated imaging. CONCLUSION: The study proved that using DL for MRI image reconstruction in orbital scans significantly cut acquisition time by 69%. This approach also enhanced image quality, reduced image noise, sharpened images, and boosted diagnostic confidence.


Assuntos
Aprendizado Profundo , Órbita , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Artefatos
4.
Cancer Immunol Immunother ; 73(1): 19, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38240863

RESUMO

BACKGROUND: GD2-directed immunotherapy is highly effective in the treatment of high-risk neuroblastoma (NB), and might be an interesting target also in other high-risk tumors. METHODS: The German-Austrian Retinoblastoma Registry, Essen, was searched for patients, who were treated with anti-GD2 monoclonal antibody (mAb) dinutuximab beta (Db) in order to evaluate toxicity, response and outcome in these patients. Additionally, we evaluated anti-GD2 antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-dependent cytotoxicity (CDC) in retinoblastoma cell lines in vitro. Furthermore, in vitro cytotoxicity assays directed against B7-H3 (CD276), a new identified potential target in RB, were performed. RESULTS: We identified four patients with relapsed stage IV retinoblastoma, who were treated with Db following autologous stem cell transplantation (ASCT). Two out of two evaluable patients with detectable tumors responded to immunotherapy. One of these and another patient who received immunotherapy without residual disease relapsed 10 and 12 months after start of Db. The other patients remained in remission until last follow-up 26 and 45 months, respectively. In vitro, significant lysis of RB cell lines by ADCC and CDC with samples from patients and healthy donors and anti-GD2 and anti-CD276-mAbs were demonstrated. CONCLUSION: Anti-GD2-directed immunotherapy represents an additional therapeutic option in high-risk metastasized RB. Moreover, CD276 is another target of interest.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Neoplasias da Retina , Retinoblastoma , Humanos , Retinoblastoma/terapia , Transplante Autólogo , Recidiva Local de Neoplasia , Imunoterapia , Gangliosídeos , Antígenos B7
5.
Acad Radiol ; 31(1): 180-186, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37280126

RESUMO

RATIONALE AND OBJECTIVES: Fluid-attenuated inversion recovery (FLAIR) imaging is playing an increasingly significant role in the detection of brain metastases with a concomitant increase in the number of magnetic resonance imaging (MRI) examinations. Therefore, the purpose of this study was to investigate the impact on image quality and diagnostic confidence of an innovative deep learning-based accelerated FLAIR (FLAIRDLR) sequence of the brain compared to conventional (standard) FLAIR (FLAIRS) imaging. MATERIALS AND METHODS: Seventy consecutive patients with staging cerebral MRIs were retrospectively enrolled in this single-center study. The FLAIRDLR was conducted using the same MRI acquisition parameters as the FLAIRS sequence, except for a higher acceleration factor for parallel imaging (from 2 to 4), which resulted in a shorter acquisition time of 1:39 minute instead of 2:40 minutes (-38%). Two specialized neuroradiologists evaluated the imaging datasets using a Likert scale that ranged from 1 to 4, with 4 indicating the best score for the following parameters: sharpness, lesion demarcation, artifacts, overall image quality, and diagnostic confidence. Additionally, the image preference of the readers and the interreader agreement were assessed. RESULTS: The average age of the patients was 63 ± 11years. FLAIRDLR exhibited significantly less image noise than FLAIRS, with P-values of< .001 and< .05, respectively. The sharpness of the images and the ability to detect lesions were rated higher in FLAIRDLR, with a median score of 4 compared to a median score of 3 in FLAIRS (P-values of<.001 for both readers). In terms of overall image quality, FLAIRDLR was rated superior to FLAIRS, with a median score of 4 vs 3 (P-values of<.001 for both readers). Both readers preferred FLAIRDLR in 68/70 cases. CONCLUSION: The feasibility of deep learning FLAIR brain imaging was shown with additional 38% reduction in examination time compared to standard FLAIR imaging. Furthermore, this technique has shown improvement in image quality, noise reduction, and lesion demarcation.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Encefálicas/patologia , Artefatos
6.
Clin Neuroradiol ; 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38082172

RESUMO

PURPOSE: Individuals with drug-resistant epilepsy may benefit from epilepsy surgery. In nonlesional cases, where no epileptogenic lesion can be detected on structural magnetic resonance imaging, multimodal neuroimaging studies are required. Breath-hold-triggered BOLD fMRI (bh-fMRI) was developed to measure cerebrovascular reactivity in stroke or angiopathy and highlights regional network dysfunction by visualizing focal impaired flow increase after vasodilatory stimulus. This regional dysfunction may correlate with the epileptogenic zone. In this prospective single-center single-blind pilot study, we aimed to establish the feasibility and safety of bh-fMRI in individuals with drug-resistant non-lesional focal epilepsy undergoing presurgical evaluation. METHODS: In this prospective study, 10 consecutive individuals undergoing presurgical evaluation for drug-resistant focal epilepsy were recruited after case review at a multidisciplinary patient management conference. Electroclinical findings and results of other neuroimaging were used to establish the epileptogenic zone hypothesis. To calculate significant differences in cerebrovascular reactivity in comparison to the normal population, bh-fMRIs of 16 healthy volunteers were analyzed. The relative flow change of each volume of interest (VOI) of the atlas was then calculated compared to the flow change of the whole brain resulting in an atlas of normal cerebral reactivity. Consequently, the mean flow change of every VOI of each patient was tested against the healthy volunteers group. Areas with significant impairment of cerebrovascular reactivity had decreased flow change and were compared to the epileptogenic zone localization hypothesis in a single-blind design. RESULTS: Acquisition of bh-fMRI was feasible in 9/10 cases, with one patient excluded due to noncompliance with breathing maneuvers. No adverse events were observed, and breath-hold for intermittent hypercapnia was well tolerated. On blinded review, we observed full or partial concordance of the local network dysfunction seen on bh-fMRI with the electroclinical hypothesis in 6/9 cases, including cases with extratemporal lobe epilepsy and those with nonlocalizing 18F-fluorodeoxyglucose positron emission tomography (FDG-PET). CONCLUSION: This represents the first report of bh-fMRI in individuals with epilepsy undergoing presurgical evaluation. We found bh-fMRI to be feasible and safe, with a promising agreement to electroclinical findings. Thus, bh-fMRI may represent a potential modality in the presurgical evaluation of epilepsy. Further studies are needed to establish clinical utility.

9.
Neuroradiology ; 65(3): 539-550, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36434312

RESUMO

PURPOSE: Patients with Moyamoya Angiopathy (MMA) require hemodynamic assessment to evaluate the risk of stroke. Hemodynamic evaluation by use of breath-hold-triggered fMRI (bh-fMRI) was proposed as a readily available alternative to the diagnostic standard [15O]water PET. Recent studies suggest voxel-wise hemodynamic delay correction in hypercapnia-triggered fMRI. The aim of this study was to evaluate the effect of delay correction of bh-fMRI in patients with MMA and to compare the results with [15O]water PET. METHODS: bh-fMRI data sets of 22 patients with MMA were evaluated without and with voxel-wise delay correction within different shift ranges and compared to the corresponding [15O]water PET data sets. The effects were evaluated combined and in subgroups of data sets with most severely impaired CVR (apparent steal phenomenon), data sets with territorial time delay, and data sets with neither steal phenomenon nor delay between vascular territories. RESULTS: The study revealed a high mean cross-correlation (r = 0.79, p < 0.001) between bh-fMRI and [15O]water PET. The correlation was strongly dependent on the choice of the shift range. Overall, no shift range revealed a significantly improved correlation between bh-fMRI and [15O]water PET compared to the correlation without delay correction. Delay correction within shift ranges with positive high high cutoff revealed a lower agreement between bh-fMRI and PET overall and in all subgroups. CONCLUSION: Voxel-wise delay correction, in particular with shift ranges with high cutoff, should be used critically as it can lead to false-negative results in regions with impaired CVR and a lower correlation to the diagnostic standard [15O]water PET.


Assuntos
Imageamento por Ressonância Magnética , Doença de Moyamoya , Humanos , Imageamento por Ressonância Magnética/métodos , Água , Circulação Cerebrovascular , Hemodinâmica , Encéfalo/irrigação sanguínea
10.
Neuroradiology ; 64(3): 553-563, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34570251

RESUMO

PURPOSE: Patients with Moyamoya Angiopathy (MMA) require hemodynamic evaluation to assess the risk of stroke. Assessment of cerebral blood flow with [15O]water PET and acetazolamide challenge is the diagnostic standard for the evaluation of the cerebral perfusion reserve (CPR). Estimation of the cerebrovascular reactivity (CVR) by use of breath-hold-triggered fMRI (bh-fMRI) as an index of CPR has been proposed as a reliable and more readily available approach. Recent findings suggest the use of resting-state fMRI (rs-fMRI) which requires minimum patient compliance. The aim of this study was to compare rs-fMRI to bh-fMRI and [15O]water PET in patients with MMA. METHODS: Patients with MMA underwent rs-fMRI and bh-fMRI in the same MRI session. Maps of the CVR gained by both modalities were compared retrospectively by calculating the correlation between the mean CVR of 12 volumes of interest. Additionally, the rs-maps of a subgroup of patients were compared to CPR-maps gained by [15O]water PET. RESULTS: The comparison of the rs-maps and the bh-maps of 24 patients revealed a good correlation (Pearson's r = 0.71 ± 0.13; preoperative patients: Pearson's r = 0.71 ± 0.17; postoperative patients: Pearson's r = 0.71 ± 0.11). The comparison of 7 rs-fMRI data sets to the corresponding [15O]water PET data sets also revealed a high level of agreement (Pearson's r = 0.80 ± 0.19). CONCLUSION: The present analysis indicates that rs-fMRI might be a promising non-invasive method with almost no patient cooperation needed to evaluate the CVR. Further prospective studies are required.


Assuntos
Imageamento por Ressonância Magnética , Doença de Moyamoya , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular/fisiologia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética/métodos , Doença de Moyamoya/diagnóstico por imagem , Estudos Retrospectivos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...